Two-component, solvent-free self-leveling epoxy coating.
DESCRIPTION TPI FS 240
This is a two-component, solvent-free, colored epoxy resin-based paint. Upon application and complete curing, the product creates a smooth, hard coating that resists common chemicals, abrasion, and water penetration.
TPI FS 240 APPLICATION
Used as a coating for concrete and screed floors subjected to low to high loads, such as:
- Flooring for warehouses, halls, workshops, repair and maintenance areas, garages, ramps, etc.
- Coating for sandblasting systems to create a rough surface.
- Suitable for applications in water tanks, food processing plants, wastewater treatment environments, etc.
Advantages of TPI FS 240
- Easy to install.
- Non-toxic.
- Because it contains no solvents, it should only be used in restricted areas.
- It prevents liquids from penetrating through.
- High resistance to chemical corrosion, impact, and abrasion.
- The surface has a glossy finish.
- Easy to clean surface.
SPECIFICATIONS
| Target | TPI FS 240 |
| Ingredient | Liquid epoxy |
| Color | Part A: Plastics – colored
Part B: Curing – Transparent Mixture: Gray, green… |
| Density | Part A: ~1.70 kg/liter
Part B: ~1.05 kg/liter Mixture: ~1.55 kg/liter |
| Packaging specifications | Part A: 20kg/carton
Part B: 5kg / carton Part A + B: 25kg / set |
| Mixing ratio | 5:1 (by weight) |
| Solid content | 100% |
| Compressive strength | > 45 N/mm2 |
| Adhesion strength | > 1.5 N/mm2 |
| Expiry | 24 months (when unopened) |
| Storage | The packaging must be intact, unopened, and undamaged.
Store in a cool, dry, shaded place at a temperature of 10°C or higher.oC to 35oC. |
Coating system and coverage:
| Coating system | 1 x primer coat: TPI Primer SB 0.2 – 0.4 kg/m²2 |
| 2 coats: TPI FS 240 0.5 kg/m²2 | |
| Sand sprinkling system | 1 x primer coat: TPI Primer SB 0.2 – 0.4 kg/m²2 |
| 1 x coating: TPI FS 240 0.5 kg/m²2 | |
| 1 layer of sand: 0.3 – 1.2 mm, 4.0 – 5.0 kg/m²2 | |
| 1 x coating: TPI FS 240 0.5 kg/m²2 | |
| Construction temperature | 10 – 30oC |
| Curing time | Facial treatment time: 80 – 180 minutes
Between coats: 8 – 20 hours Complete curing: 7 days |
INSTRUCTIONS FOR USE
Surface preparation
- The concrete surface must be solid and have a minimum compressive strength of 25 N/mm² and a minimum adhesion strength of 1.5 N/mm².
- The surface must be clean, dry, and free of contaminants such as dirt, oil, grease, old coatings, and surface maintenance compounds.
- Weak concrete and dirt must be removed. Surface defects such as pits, voids, cracks, and bumps must be treated and smoothed.
Check for moisture levels and apply the primer.
- Check surface moisture, relative humidity, and dew point before application.
- If the surface moisture content is < 4.5%, use an epoxy primer. TPI Primer SB or TPI Primer FS.
- If the surface moisture content is >= 4.5%, use a moisture-resistant epoxy primer. TPI Primer MB.
Mixing sequence
- TPI FS 240 It is supplied in a two-component kit consisting of a base component A and a curing agent B.
- Before mixing, stir ingredient A thoroughly. Once all of ingredient B has been added to ingredient A, continue mixing for 3 minutes until a homogeneous mixture is achieved.
- Do not mix for too long to reduce air entrainment.
- Use a low-speed stirrer (300-400 rpm) or other suitable mixing equipment.
Applying the coating
- Class TPI FS 240 The first coat must be applied as a base coat using a rubbing motion to ensure an even finish. The first coat must be allowed to dry for at least 8 hours at 20°C or 4 hours at 35°C.
- The maximum coating time should be adhered to.
- Class TPI FS 240 The second layer must be constructed precisely as described above, perpendicular to the first layer.
- A short-bristled roller can be used for application.
Toilet
- Clean equipment and tools immediately after use. Once the paint has hardened, it can only be removed by mechanical means.
- Toilet TPI FS 240 Spills must be cleaned up immediately using specialized brushes, mechanical methods, wet methods, scrubbing, vacuum cleaning techniques, appropriate detergents, and wax.
IMPORTANT NOTE
- Construction is not permitted. TPI FS 240 Up onto the surface where the moisture content increases.
- Do not replace the liner with another product.
- TPI FS 240 Newly constructed buildings must be protected from moisture, condensation, and water for a minimum of 24 hours.
- The primer will help prevent surface blistering during application.
HEALTH AND SAFETY INFORMATION
Occupational safety and health: Appropriate personal protective equipment, including safety glasses and gloves, should be worn when using this product. It may cause allergic reactions upon contact with eyes, skin, or mucous membranes.
Ecology: Do not dispose of into water sources or soil.
Transport: Not dangerous.
Refer to the product's Material Safety Data Sheet (MSDS) and other relevant safety data sheets.